Brazilian Journal of Anesthesiology
https://bjan-sba.org/article/doi/10.1016/j.bjane.2021.09.003
Brazilian Journal of Anesthesiology
Case Report

Noninvasive intracranial pressure real-time waveform analysis monitor during prostatectomy robotic surgery and Trendelenburg position: case report

Monitor de análise de onda em tempo real de pressão intracraniana não invasiva durante cirurgia robótica de prostatectomia e posição de Trendelenburg: relato de caso

Gabriela Tognini Saba, Vinicius Caldeira Quintão, Suely Pereira Zeferino, Claudia Marquez Simões, Rafael Ferreira Coelho, Arnaldo Fazoli, William Nahas, Gustavo Henrique Frigieri Vilela, Maria José Carvalho Carmona

Downloads: 1
Views: 969

Abstract

Both robotic surgery and head-down tilt increase intracranial pressure by impairing venous blood outflow. Prostatectomy is commonly performed in elderly patients, who are more likely to develop postoperative cognitive disorders. Therefore, increased intracranial pressure could play an essential role in cognitive decline after surgery. We describe a case of a 69-year-old male who underwent a robotic prostatectomy. Noninvasive Brain4careTM intraoperative monitoring showed normal intracranial compliance during anesthesia induction, but it rapidly decreased after head-down tilt despite normal vital signs, low lung pressure, and adequate anesthesia depth. We conclude that there is a need for intraoperative intracranial compliance monitoring since there are major changes in cerebral compliance during surgery, which could potentially allow early identification and treatment of impaired cerebral complacency.

Keywords

Head-down tilt;  Intracranial pressure;  Robotic surgical procedures

References

1 G.H. Vilela, B. Cabella, S. Mascarenhas, et al. Validation of a New Minimally Invasive Intracranial Pressure Monitoring Method by Direct Comparison with an Invasive Technique Acta Neurochir Suppl, 122 (2016), pp. 97-100

2 M.K. Lashutka, A. Chandra, H.N. Murray, et al. The relationship of intraocular pressure to intracranial pressure Ann Emerg Med, 43 (2004), pp. 585-591 Erratum in: Ann Emerg Med. 2004;44:561

3 T. Kirk, K. Jones, S. Miller, et al. Measurement of intraocular and intracranial pressure: is there a relationship? Ann Neurol, 70 (2011), pp. 323-326

4 S. Mascarenhas, G.H. Vilela, C. Carlotti, et al. The new ICP minimally invasive method shows that the Monro-Kellie doctrine is not valid Acta Neurochir Suppl, 114 (2012), pp. 117-120

5 G. Frigieri, R.A.P. Andrade, C. Dias, et al. Analysis of a Non-invasive Intracranial Pressure Monitoring Method in Patients with Traumatic Brain Injury Acta Neurochir Suppl, 126 (2018), pp. 107-110

6 R.J. Rosenthal, J.R. Hiatt, E.H. Phillips, et al. Intracranial pressure. Effects of pneumoperitoneum in a large-animal model Surg Endosc, 11 (1997), pp. 376-380