Minimum anesthetic volume in regional anesthesia by using ultrasound-guidance
Volume mínimo de anestésico em anestesia regional guiada por ultrassom
Alessandro Di Filippo; Silvia Falsini; Chiara Adembri
Abstract
Keywords
Resumo
Palavras-chave
References
Koscielniak-Nielsen ZJ. Ultrasound-guided peripheral nerve blocks: what are the benefits?. Acta Anaesthesiol Scand. 2008;52:727-37.
Wadhwa A, Kandadai SK, Tongpresert S. Ultrasound guidance for deep peripheral nerve blocks: a brief review. Anesthesiol Res Pract. 2011;2011:262070.
McNaught A, Shastri U, Carmichael N. Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stimulation for interscalene block. Br J Anaesth. 2011;106:124-30.
Ponrouch M, Bouic N, Bringuier S. Estimation and pharmacodynamic consequences of the minimum effective anesthetic volumes for median and ulnar nerve blocks: a randomized, double-blind, controlled comparison between ultrasound and nerve stimulation guidance. Anesth Analg. 2010;111:1059-64.
Danelli G, Ghisi D, Fanelli A. The effects of ultrasound guidance and neurostimulation on the minimum effective anesthetic volume of mepivacaine 1.5% required to block the sciatic nerve using the subgluteal approach. Anesth Analg. 2009;109:1674-8.
Casati A, Baciarello M, Di Cianni S. Effects of ultrasound guidance on the minimum effective anesthetic volume required to block the femoral nerve. Br J Anaesth. 2007;98:823-7.
O’Donnell BD, Iohom G. An estimation of the minimum effective anesthetic volume of 2% lidocaine in ultrasound-guideed axillary brachial plexus block. Anesthesiology. 2009;111:25-9.
Durham SD, Flournoy N, Rosenberger WF. A random walk rule for the clinical trials I phase. Biometrics. 1997;53:745-60.
O’Donnell BD, Iohom G. Local anesthetic dose and volume used in ultrasound-guided peripheral nerve blockade. Int Anesthesiol Clin. 2010;48:45-58.
Harper GK, Stafford MA, Hill DA. Minimum volume of local anaesthetic required to surround each of the constituent nerves of the axillary brachial plexus, using ultrasound guidance: a pilot study. Br J Anaesth. 2010;104:633-6.
González AP, Bernucci F, Pham K. Minimum effective volume of lidocaine for double-injection ultrasound-guided axillary block. Reg Anesth Pain Med. 2013;38:16-20.
Gautier P, Vandepitte C, Ramquet C. The minimum effective anesthetic volume of 0.75% ropivacaine in ultrasound-guided interscalene brachial plexus block. Anesth Analg. 2011;113:951-5.
Riazi S, Carmichael N, Awad I. Effect of local anaesthetic volume (20 vs 5 ml) on the efficacy and respiratory consequences of ultrasound-guided interscalene brachial plexus block. Br J Anaesth. 2008;101:549-56.
Renes SH, Rettig HC, Gielen MJ. Ultrasound-guided low-dose interscalene brachial plexus block reduces the incidence of hemidiaphragmatic paresis. Reg Anesth Pain Med. 2009;34:498-502.
Renes SH, van Geffen GJ, Rettig HC. Minimum effective volume of local anesthetic for shoulder analgesia by ultrasound-guided block at root C7 with assessment of pulmonary function. Reg Anesth Pain Med. 2010;35:529-34.
Duggan E, El Beheiry H, Perlas A. Minimum effective volume of local anesthetic for ultrasound-guided supraclavicular brachial plexus block. Reg Anesth Pain Med. 2009;34:215-8.
Tran de QH, Dugani S, Correa JA. Minimum effective volume of lidocaine for ultrasound-guided supraclavicular block. Reg Anesth Pain Med. 2011;36:466-9.
Tran de QH, Clemente A, Tran DQ. A comparison between ultrasound-guided infraclavicular block using the “double bubble” sign and neurostimulation-guided axillary block. Anesth Analg. 2008;107:1075-8.
Eichenberger U, Stöckli S, Marhofer P. Minimal local anesthetic volume for peripheral nerve block: a new ultrasound-guided, nerve dimension-based method. Reg Anesth Pain Med. 2009;34:242-6.
Marhofer P, Schrögendorfer K, Wallner T. Ultrasonographic guidance reduces the amount of local anesthetic for 3-in-1 blocks. Reg Anesth Pain Med. 1998;23:584-8.
Latzke D, Marhofer P, Zeitlinger M. Minimal local anaesthetic volumes for sciatic nerve block: evaluation of ED 99 in volunteers. Br J Anaesth. 2010;104:239-44.
Liu FC, Liou JT, Tsai YF. Efficacy of ultrasound-guided axillary brachial plexus block: a comparative study with nerve stimulator-guided method. Chang Gung Med J. 2005;28:396-402.
Williams SR, Chouinard P, Arcand G. Ultrasound guidance speeds execution and improves the quality of supraclavicular block. Anesth Analg. 2003;97:1518-23.
Dingemans E, Williams SR, Arcand G. Neurostimulation in ultrasound-guided infraclavicular block: a prospective randomized trial. Anesth Analg. 2007;104:1275-80.
Taboada M, Rodríguez J, Amor M. Is ultrasound guidance superior to conventional nerve stimulation for coracoid infraclavicular brachial plexus block?. Reg Anesth Pain Med. 2009;34(4):357-60.
Marhofer P, Schrögendorfer K, Koinig H. Ultrasonographic guidance improves sensory block and onset time of three-in-one blocks. Anesth Analg. 1997;85:854-7.
Walker KJ, McGrattan K, Aas-Eng K. Ultrasound guidance for peripheral nerve blockade. Cochrane Database Syst Rev. 2009;4:CD006459.
Luyet C, Schüpfer G, Wipfli M. Different learning curves for axillary brachial plexus block: ultrasound guidance versus nerve stimulation. Anesthesiol Res Pract. 2010;2010:309462.