When one port does not return blood: two case reports of rare causes for misplaced central venous catheters

Quando uma porta não apresenta retorno sanguíneo: relato de dois casos de causas raras de mau posicionamento de cateter venoso central

Sandra Pereira; César Preto; Carla Pinho; Pedro Vasconcelos

Downloads: 0
Views: 612

Abstract

We present two cases of misplaced central venous catheters having in common theabsence of free blood return from one lumen immediately after placement. The former is acase of right hydrothorax associated with central venous catheterization with the catheter tipin intra-pleural location. In this case the distal port was never patent. In the latter case therewas an increased aspiration pressure through the middle port due to a catheter looping.The absence of free flow on aspiration from one lumen of a central catheter should not beundervalued. In these circumstances the catheter should not be used and needs to be removed.

Keywords

Central venous catheter, Hydrothorax, Looping, Malposition

Resumo

Apresentamos dois casos de mau posicionamento de cateter venoso central. Têmem comum a ausência do retorno sanguíneo livre em um dos lúmens imediatamente após acolocac¸ão. O primeiro é um caso de hidrotórax direito associado ao cateterismo venoso central,com a ponta do cateter em localizac¸ão intrapleural. Nesse caso, a porta distal nunca estevepatente. No segundo caso houve um aumento da pressão de aspirac¸ão através da porta medialpor causa da formac¸ão de alc¸a no cateter.A ausência de fluxo livre na aspirac¸ão de um lúmen do cateter central não deve ser subesti-mada. Nessas circunstâncias, o cateter não deve ser usado e deve ser removido.

Palavras-chave

Cateter venoso central, Hidrotórax, Alça, Mau posicionamento

References

McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med.. 2003;348:1123-33.

Duntley P, Siever J, Korwes ML. Vascular erosion by cen-tral venous catheters. Clinical features and outcome. Chest.. 1992;101:1633e1638.

Gibson F, Bodenham A. Misplaced central venous catheters: applied anatomy and practical management. Br J Anaesth.. 2013;110:333-46.

Rudge CJ, Bewick M, Mccoll I. Hydrothorax after central venous catheterization. Br Med J.. 1973;3:23-5.

Iberti TJ, Katz LB, Reiner MA. Hydrothorax as a late complication of central venous indwelling catheters. Surgery.. 1983;94:842-6.

Kunizawa A, Fujioka M, Mink S. Central venous catheter-induced delayed hydrothorax via progressive erosion of central venous wall. Minerva Anestesiol.. 2010;76:868-71.

Maroun R, Chalhoub M, Harris K. Right internal jugular venous cannulation complicated by tension hydrothorax. Heart Lung.. 2013;42:372-4.

Bannon MP, Heller SF, Rivera M. Anatomic considerations for central venous cannulation. Risk Manag Healthc Policy.. 2011;4:27-39.

Malatinsk´y J, Kadlic T, Májek M. Misplacement and loop formation of central venous catheters. Acta Anaesthesiol Scand.. 1976;20:237-47.

Juneja R, Mehta Y. Looping of a subclavian catheter: an unusual presentation. J Cardiothorac Vasc Anesth.. 1994;8:255e257.

Bagul NB, Menon NJ, Pathak R. Knot in the cavae: an unusual complication of swan-ganz catheters. Eur J Vasc Endovasc Surg.. 2005;29:651e653.

Vetrugno L, Piccoli G, Costa MG. The dos and do knots of central venous catheterization. J Clin Anesth.. 2012;24:148-50.

Karakitsos D, Labropoulos N, De Groot E. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care.. 2006;10:R162.

Leung J, Duffy M, Finckh A. Real-time ultrasonographically-guided internal jugular vein catheterization in the emer-gency department increases success rates and reduces complications: a randomized, prospective study. Ann Emerg Med.. 2006;48:540-7.

Mey U, Glasmacher A, Hahn C. Evaluation of an ultrasound-guided technique for central venous access via the internal jugular vein in 493 patients. Support Care Cancer.. 2003;11:148-55.

5dcd9be00e88257c5ebf58f2 rba Articles
Links & Downloads

Braz J Anesthesiol

Share this page
Page Sections