Oxygen concentrators performance with nitrous oxide at 50:50 volume
Desempenho de concentradores de oxigênio com óxido nitroso em volume de 50:50
Jorge Ronaldo Moll; Joaquim Edson Vieira; Judymara Lauzi Gozzani; Lígia Andrade Silva Telles Mathias
Abstract
Keywords
Resumo
Palavras-chave
References
Friesen RM, Raber MB, Reimer DH. Oxygen concentrators: a primary oxygen supply source. Can J Anaesth. ;46:1190-1185.
Arrowsmith LW. Oxygen concentrators for medical gas pipeline systems. J Inst Hosp Eng. ;43:8-6.
Moll JR, Moll AVS, Guttman A. Usinas concentradoras de oxigênio: evolução da fração inspirada de oxigênio e repercussões no paciente anestesiado em sistema com absorvedor de CO2. Estudo piloto.. Rev Bras Anestesiol. ;57:649-57 [Portuguese].
Carter JA, Baskett PFJ, Simpson PJ. The 'Permox' oxygen concentrator. Its mode of action, performance and potential application.. Anaesthesia. ;40:560-565.
Fenton PM. The Malawi anaesthetic machine. Experience with a new type of anaesthetic apparatus for developing countries. Anaesthesia. ;44:498-503.
Shrestsha BM, Singh BB, Gautam MP. The oxygen concentrator is a suitable alternative to oxygen cylinders in Nepal. Can J Anaesth. ;49:8-12.
Whitley E, Ball J. Statistics review 3: sample size calculation. Crit Care. ;6:335-341.
Parker CJ, Snowdon SL. Predicted and measured oxygen concentrations in the circle system using low fresh gas flows with oxygen supplied by an oxygen concentrator. Br J Anaesth. ;61:397-402.
Friesen RM. Oxygen concentrators and the practice of anaesthesia. Can J Anaesth. ;39:R89-R80.
Grano JT, Roberts AL, Bigley AJ. Determination of the mini-mal fresh gas flow to maintain a therapeutic inspired oxygen concentration in a semi closed anesthesia circle system using an oxygen concentrator as the oxygen source. Technical Report. .
Rathgeber J, Züchner K, Kietzmann D. Efficiency of a mobile oxygen concentrator for mechanical ventilation in anesthesia. Studies with a metabolic lung model and early clinical results.. Anaesthesist. ;44:643-650.
Brattwall M, Warrén-Stomberg M, Hesselvik F. Brief review: theory and practice of minimal fresh gas flow anesthesia. Can J Anaesth. ;59:797-785.
Mokuolu OA, Ajayi OA. Use of an oxygen concentrator in a Nigerian neonatal unit: economic implications and reliability. Ann Trop Paediatr. ;22:209-212.
L'Her P, Tchoua R, Hutin R. The problem of oxygen in developing countries. Med Trop (Mars). ;66:638-631.
Shankar KB, Moseley HS, Mushlin PS. Anaesthesia in Barbados. Can J Anaesth. ;44:568-559.
Sanders RD, Weimann J, Maze M. Biologic effects of nitrous oxide: a mechanistic and toxicologic review. Anesthesiology. ;109:707-722.
Myles PS, Leslie K, Chan MT. Avoidance of nitrous oxide for patients undergoing major surgery: a randomized controlled trial. Anesthesiology. ;107:231-221.
Herff H, Paal P, von Goedecke A. Fatal errors in nitrous oxide delivery. Anaesthesia. ;62:1206-1202.
Enlund M, Edmark L, Revenäs B. Ceasing routine use of nitrous oxide - a follow up. Br J Anaesth. ;90:686-688.
Turan A, Mascha EJ, You J. The association between nitrous oxide and postoperative mortality and morbidity after noncardiac surgery. Anesth Analg. ;116:1033-1026.