Oxygen concentrators performance with nitrous oxide at 50:50 volume

Desempenho de concentradores de oxigênio com óxido nitroso em volume de 50:50

Jorge Ronaldo Moll; Joaquim Edson Vieira; Judymara Lauzi Gozzani; Lígia Andrade Silva Telles Mathias

Downloads: 0
Views: 716

Abstract

Background and objectives: Few investigations have addressed the safety of oxygen from concentrators for use in anesthesia in association with nitrous oxide. This study evaluated the percent of oxygen from a concentrator in association with nitrous oxide in a semi-closed rebreathing circuit. Methods: Adult patients undergoing low risk surgery were randomly allocated into two groups, receiving a fresh gas flow of oxygen from concentrators (O293) or of oxygen from concentrators and nitrous oxide (O293N2O). The fraction of inspired oxygen and the percentage of oxygen from fresh gas flow were measured every 10 min. The ratio of FiO2/oxygen concentration delivered was compared at various time intervals and between the groups. Results: Thirty patients were studied in each group. There was no difference in oxygen from concentrators over time for both groups, but there was a significant improvement in the FiO2 (p < 0.001) for O293 group while a significant decline (p < 0.001) for O293N2O. The FiO2/oxygen ratio varied in both groups, reaching a plateau in the O293 group. Pulse oximetry did not fall below 98.5% in either group. Conclusion: The FiO2 in the mixture of O293 and nitrous oxide fell during the observation period although oxygen saturation was higher than 98.5% throughout the study. Concentrators can be considered a stable source of oxygen for use during short anesthetic procedures, either pure or in association with nitrous oxide at 50:50 volume.

Keywords

Oxygen inhalation therapy, Nitrous oxide, Equipment and supplies, Anesthesia, Inhalation, Developing countries

Resumo

Justificativa e objetivos: poucas pesquisas abordaram a segurança do oxigênio a partir de concentradores para uso em anestesia em associação com óxido nitroso. Este estudo avaliou a porcentagem de oxigênio a partir de um concentrador em associação com óxido nitroso em um circuito de reinalação semifechado. Métodos: pacientes adultos submetidos à cirurgia de baixo risco foram alocados aleatoriamente em dois grupos e receberam um fluxo de gases frescos de concentradores de oxigênio (O293) ou de concentradores de oxigênio e óxido nitroso (O293N2O). A fração inspirada de oxigênio e a porcentagem do fluxo de gases frescos de oxigênio foram medidas a cada 10 minutos. O razão da concentração liberada de FiO2/oxigênio foi comparada em diferentes intervalos de tempo e entre os grupos. Resultados: foram avaliados em cada grupo 30 pacientes. Não houve diferença em oxigênio a partir dos concentradores ao longo do tempo para ambos os grupos, mas houve uma melhora significativa da FiO2 (p < 0,001) no grupo O293, enquanto houve uma queda significativa (p < 0,001) no grupo O293N2O. A razão FiO2/oxigênio variou em ambos os grupos e atingiu um patamar no grupo O293. A oximetria de pulso não caiu abaixo de 98,5% em ambos os grupos. Conclusão: a FiO2 na mistura de O293 e óxido nitroso caiu durante o período de observação, embora a saturação de oxigênio tenha ficado acima de 98,5% durante todo o estudo. Os concentradores podem ser considerados uma fonte estável de oxigênio para uso durante procedimentos anestésicos de curta duração, tanto puro quanto em associação com óxido nitroso em volume de 50:50.

Palavras-chave

Oxigenoterapia, Óxido nitroso, Equipamentos e suprimentos, Anestesia, Inalação, Países em desenvolvimento

References

Friesen RM, Raber MB, Reimer DH. Oxygen concentrators: a primary oxygen supply source. Can J Anaesth. ;46:1190-1185.

Arrowsmith LW. Oxygen concentrators for medical gas pipeline systems. J Inst Hosp Eng. ;43:8-6.

Moll JR, Moll AVS, Guttman A. Usinas concentradoras de oxigênio: evolução da fração inspirada de oxigênio e repercussões no paciente anestesiado em sistema com absorvedor de CO2. Estudo piloto.. Rev Bras Anestesiol. ;57:649-57 [Portuguese].

Carter JA, Baskett PFJ, Simpson PJ. The 'Permox' oxygen concentrator. Its mode of action, performance and potential application.. Anaesthesia. ;40:560-565.

Fenton PM. The Malawi anaesthetic machine. Experience with a new type of anaesthetic apparatus for developing countries. Anaesthesia. ;44:498-503.

Shrestsha BM, Singh BB, Gautam MP. The oxygen concentrator is a suitable alternative to oxygen cylinders in Nepal. Can J Anaesth. ;49:8-12.

Whitley E, Ball J. Statistics review 3: sample size calculation. Crit Care. ;6:335-341.

Parker CJ, Snowdon SL. Predicted and measured oxygen concentrations in the circle system using low fresh gas flows with oxygen supplied by an oxygen concentrator. Br J Anaesth. ;61:397-402.

Friesen RM. Oxygen concentrators and the practice of anaesthesia. Can J Anaesth. ;39:R89-R80.

Grano JT, Roberts AL, Bigley AJ. Determination of the mini-mal fresh gas flow to maintain a therapeutic inspired oxygen concentration in a semi closed anesthesia circle system using an oxygen concentrator as the oxygen source. Technical Report. .

Rathgeber J, Züchner K, Kietzmann D. Efficiency of a mobile oxygen concentrator for mechanical ventilation in anesthesia. Studies with a metabolic lung model and early clinical results.. Anaesthesist. ;44:643-650.

Brattwall M, Warrén-Stomberg M, Hesselvik F. Brief review: theory and practice of minimal fresh gas flow anesthesia. Can J Anaesth. ;59:797-785.

Mokuolu OA, Ajayi OA. Use of an oxygen concentrator in a Nigerian neonatal unit: economic implications and reliability. Ann Trop Paediatr. ;22:209-212.

L'Her P, Tchoua R, Hutin R. The problem of oxygen in developing countries. Med Trop (Mars). ;66:638-631.

Shankar KB, Moseley HS, Mushlin PS. Anaesthesia in Barbados. Can J Anaesth. ;44:568-559.

Sanders RD, Weimann J, Maze M. Biologic effects of nitrous oxide: a mechanistic and toxicologic review. Anesthesiology. ;109:707-722.

Myles PS, Leslie K, Chan MT. Avoidance of nitrous oxide for patients undergoing major surgery: a randomized controlled trial. Anesthesiology. ;107:231-221.

Herff H, Paal P, von Goedecke A. Fatal errors in nitrous oxide delivery. Anaesthesia. ;62:1206-1202.

Enlund M, Edmark L, Revenäs B. Ceasing routine use of nitrous oxide - a follow up. Br J Anaesth. ;90:686-688.

Turan A, Mascha EJ, You J. The association between nitrous oxide and postoperative mortality and morbidity after noncardiac surgery. Anesth Analg. ;116:1033-1026.

5dcda36b0e8825eb07bf58f2 rba Articles
Links & Downloads

Braz J Anesthesiol

Share this page
Page Sections