Conduta anestésica em criança com osteogênese imperfeita e hemorragia epidural

Anesthesia management in a child with osteogenesis imperfecta and epidural

Mehmet Ali Erdoğ; an; Mukadder Sanlı; ; Mehmet Ozcan Ersoy

Downloads: 0
Views: 815

Resumo

Osteogênese imperfeita (OI) é o resultado de uma mutação genética que causa a formação defeituosa ou insuficiente de colágeno. OI pode causar várias complicações anestésicas por causa do manejo difícil das vias aéreas, da presença de deformidade da coluna vertebral, de doenças respiratórias, anomalias cardíacas, distúrbio da função plaquetária, risco de hipertermia, invaginação bacilar, deformidades ósseas e distúrbios metabólicos. A abordagem anestésica de pacientes com OI deve ser feita com cautela, por causa do risco de certas complicações respiratórias. Esses riscos são causados por deformidade do tórax, fraturas ósseas durante o movimento ou mudança de posição, fraturas mandibulares e cervicais relacionadas à intubação, intubação difícil e hipertermia maligna. As técnicas anestésicas com o uso de anestesia venosa total (AVT) e máscara laríngea são adequadas para o manejo de paciente pediátrico com OI. No entanto, essas técnicas ainda não foram mencionadas como úteis em relatos de casos neurocirúrgicos. Neste estudo, apresentamos o uso de AVT e máscara laríngea ProSeal (MLP) em uma criança com OI e hemorragia epidural. Concluímos que a MLP e a AVT podem ser usadas com segurança no manejo anestésico de pacientes com OI e problemas anestésicos graves.

Palavras-chave

DOENÇAS, Óssea, EQUIPAMENTOS, Máscara laríngea, Osteogênese Imperfeita, Hematoma Epidural Craniano, TÉCNICAS ANESTÉSICAS, Geral, venosa

Abstract

Osteogenesis Imperfecta (OI) results from gene mutation that causes defective or insuffi cient collagen formation. It may cause various anesthetic complications due to the diffi culty in airway management, existence of spinal deformity, respiratory disorders, cardiac anomalies, thrombocyte function disorder, risk of hyperthermia, bacillary invagination, bone deformities and metabolic disorders. The anesthesia management of OI patients should be exercised with caution given certain risks of respiratory disorders. These risks are due to thorax deformity, bone fractures during moving or changing position, mandibular and cervical fractures related with intubation, diffi cult intubation and malignant hyperthermia. The anesthetic technique using Total Intravenous Anesthesia (TIVA) and laryngeal mask airway is suitable for pediatric patient care with OI. However, these techniques have not yet been reported as useful in neurosurgery case reports. In this study, we present the use of TIVA and ProSeal Laringeal Mask in a child with OI and epidural hemorrhage. We came to the conclusion that LMA and TIVA can safely be used in the anesthetic management of OI patients with severe anesthetic problems.

Keywords

Anesthesia, Anesthesia, Intravenous, Hematoma, Epidural, Cranial, Laryngeal Masks, Osteogenesis Imperfect

References

Bissonnette B, Luginbuehl I, Marciniak B, Dalens B. Osteogenesis imperfekta, syndromes. 2005:618-621.

Baum VC, O'Flaherty JE. Anesthesia for genetic, metabolic, and dysmorphic syndromes of childhood. 2007:283-285.

Porsborg P, Astrup G, Bendixen D, Lund AM, Ording H. Osteogenesis imperfekta and malingnant hyperthermia: Is there a relationship?. Anaesthesia. 1996;51:863-865.

Oakley I, Reece LP. Anesthetic implications fort the patient with osteogenesis imperfecta. AANA Journal. 2010;78:47-53.

Ogawa S, Okutanı R, Suehıro K. Anesthetic management using total intravenous anaesthsia with remifentanil in a child with osteogenesis imperfecta. J Anesth. 2009;23:123-125.

Santos ML, Anez C, Fuentes A, Mendez B, Perinan R, Maria R. Airway management with ProSeal LMA in a patient with osteogenesis imperfecta. Anesth Analg. 2006;103.

Fulderer S, Stanek A, Karbowski A, Eckardt A. Intraoperative hyperpyrexia in patients with osteogenesis imperfecta. Z Orthop ıhr Grenzgeb. 2000;138:136-139.

Kostopanagiotou G, Coussi T, Tsaroucha N, Voros D. Anaesthesia using a larygeal mask airway in a patient with osteogenesis imperfecta. Anaesthesia. 2000;55.

Karabıyık L, Parpucu M, Kurtipek O. Total intravenous anaesthesia and the use of an intubating laryngeal mask in a patient with osteogenesis imperfecta. Acta Anaesthesiol Scand. 2002;46:618-619.